Venturi Scrubber Optimization Testing PDF Print E-mail
Air Control Techniques, P.C. conducted a series of diagnostic tests and internal inspections of a new venturi scrubber to determine the reasons that the unit failed to achieve the levels guaranteed by the scrubber vendor. It was demonstrated that excessive emissions were due to a combination of (1) liquid reentrainment problems and (2) the penetration of particulate matter in the 0.1 to 0.3 micrometer size range. Air Control Techniques, P.C helped the plant minimize the reentrainment problems and demonstrated that the submicrometer-sized particulate was due to the homogeneous nucleation of potassium chloride vaporized from the limestone in the kiln. Because the potassium chloride could not be economically controlled, Air Control Techniques, P.C helped the plant re-negotiate reasonable permit limits.
 